The worlds first production Infinity Turbine IT10 5-12 kw waste heat to power generator, based on the Organic Rankine Cycle (ORC) turbine that generates electricity.

http://www.infinityturbine.com

This video shows our first prototype running on R134 refrigerant. The turbine is turning (no load) at about 20,000 rpm and with load at about 8,000 rpm. Most of the noise will be taken care of by use of a muffler system for the feed pump. The high pitch whine is the turbine. Design sound is about 45 dB.

The first production units will be with permanent magnet alternators. Custom AC units in 50 hz or 60 hz will be available shortly.

Used in geothermal, solar and waste heat (industrial waste heat, gas turbine waste heat, diesel engine waste heat). Excess heat from the system output can be used for CHP applications, including desalination, hot water, air conditioning, chiller and process heat.

The turbine will operate off low grade industrial waste heat. It will also operate from geothermal, hot springs, oil well producer water or solar collector heat in the 70-150 C range.

The evaporator and condenser exit may operate in conjunction with a secondary heat exchanger for CHP hot water or chiller applications. It may also be used in tandem with a CHP, air cooling tower, or ground based geothermal system.

The IT10 is a 5-12 kilowatt power producing unit which operates off of waste heat, by vaporizing and pressurizing a environmentally friendly refrigerant which spins a turbine generator.

The unit produces 48 Volts DC. A standard inverter can convert the VDC to AC power, stand-alone or grid connect, and in 50hz or 60hz.

The IT10 is a rack-mounte plug-and-play ORC unit which can be numbered up in series to 100 kw. For AC applications, we’re offering a fully enclosed silent generation unit.

For larger applications, we have the IT250 and IT500.

For Geothermal applications (Enhanced Geothermal System (EGS)), you may utilize oil and gas wells, or abandoned wells that reach depths to get temperatures greater than 150 deg. C. In general, you may sink a deep well anywhere in the continental USA around a depth of 15,000 ft to reach this temperature. The diameter of the well will determine the maximum power you can reach with this type of power generating system. Another example of utilizing geothermal resources is at Chena Hot Springs, in Alaska, or The Geysers in northern California, or Puna Geothermal Venture in Hawaii, or Mammoth-Pacific geothermal power plants at Casa Diablo in California.

For diesel generator sets (CHP), you can first use the heat to make additional power, then still use the leftover heat for CHP.

For Solar Options you can use resource heat from parabolic trough solar, tube solar, or other means of solar heated thermal liquid.

Evaporator Exit Heat: Can be used for saltwater desalination, fresh water maker, chiller, hot water or additional process heat, such as drying and other applications (lumber dry kiln, firewood dry kiln, hardwood drykiln, greenhouse, etc.).

Condenser Exit Heat: Can be used for the production of secondary energy products, like hot water, chilled water or district heating, such as in radiant floor heating, or greenhouse heat.

This system may be able to access renewable (green) energy credits, as well as CO2 offset credits, which are worth as much as 25 Euro a ton.

This system is similar in function to the system at Chena Hot Springs, where a organic Rankine cycle is used to produce power from a geothermal source.

For more information:

http://www.infinityturbine.com

Duration : 0:3:5

Read the rest of this entry »

Technorati Tags: , , , , , , , , , , , , , , , ,

PostHeaderIcon Infinity Turbine IT10 5-12 kw ORC - Organic Rankine Cycle - Waste Heat to Power Generator


The Infinity Turbine IT10 5-12 kw is a waste heat to power generator, based on the Organic Rankine Cycle (ORC) turbine that generates electricity.

Used in geothermal, solar and waste heat (industrial waste heat, gas turbine waste heat, diesel engine waste heat). Excess heat from the system output can be used for CHP applications, including desalination, hot water, air conditioning, chiller and process heat.

The turbine will operate off low grade industrial waste heat. It will also operate from geothermal, hot springs, oil well producer water or solar collector heat, as long as there is a 125 deg. F (52 deg C) heat differential between the evaporator and condenser.

The condenser may operate off of a secondary heat exchanger for CHP hot water or chiller applications. It may also be used in tandem with a CHP, air cooling tower, or ground based geothermal system.

The IT10 is a 5-12 kilowatt power producing unit which operates off of waste heat, by vaporizing and pressurizing a environmentally friendly refrigerant which spins a turbine generator.

The unit produces 48-300 Volts DC. A standard inverter can convert the VDC to AC power, stand-alone or grid connect, and in 50hz or 60hz.

The IT10 is a rack-mounte plug-and-play ORC unit which can be numbered up in series to 100 kw.

For larger applications, we have the IT250 and IT500.

For Geothermal applications (Enhanced Geothermal System (EGS)), you may utilized oil and gas wells, or abandoned wells that reach depths to get temperatures greater than 150 deg. C. In general, you may sink a deep well anywhere in the continental USA around a depth of 15,000 ft to reach this temperature. The diameter of the well will determine the maximum power you can reach with this type of power generating system. Another example of utilizing geothermal resources is at Chena Hot Springs, in Alaska, or The Geysers in northern California, or Puna Geothermal Venture in Hawaii, or Mammoth-Pacific geothermal power plants at Casa Diablo in California.

For diesel generator sets (CHP), you can first use the heat to make additional power, then still use the leftover heat for CHP.

For Solar Options you can use resource heat from parabolic trough solar, tube solar, or other means of solar heated thermal liquid.

Evaporator Exit Heat: Can be used for saltwater desalination, fresh water maker, chiller, hot water or additional process heat, such as drying and other applications (lumber dry kiln, firewood dry kiln, hardwood drykiln, greenhouse, etc.).

Condenser Exit Heat: Can be used for the production of secondary energy products, like hot water, chilled water or district heating, such as in radiant floor heating, or greenhouse heat.

This system may be able to access renewable (green) energy credits, as well as CO2 offset credits, which are worth as much as 25 Euro a ton.

This system is similar in function to the system at Chena Hot Springs, where a organic Rankine cycle is used to produce power from a geothermal source.

For more information:

http://www.infinityturbine.com

Duration : 0:4:2

Read the rest of this entry »

Technorati Tags: , , , , , , , , , , , , , , ,

PostHeaderIcon Biomass To Power - Infinity Turbine Biomass Unit


The Infinity Turbine by Global Energy is a biomass, geothermal, solar and waste heat (industrial waste heat, gas turbine waste heat, diesel engine waste heat) Organic Rankine Cycle (ORC) turbine that generates electricity or via a PTO shaft horsepower for pumps, compressors and other equipment. Excess heat from the system output can be used for CHP applications, including desalination, hot water and process heat.

This video shows the Waterwide Solid Fuel biomass burner. The output can be used in a boiler to produce hot liquid which can be used by the Infinity Turbine to generate electricity.

The turbine will operate off of any thermal fluid, geothermal or low grade industrial waste heat. It will also operation from solar collector heat, as long as there is a 125 deg. F (65 deg C) heat differential between the evaporator and condenser.

The condenser may operate off of a secondary heat exchanger for CHP hot water or chiller applications. It may also be used in tandem with a air cooling tower, or ground based geothermal system.

Since the unit is skid mounted, it can be used on site or made portable by installing in a standard 20 foot ISO Ocean Shipping Container.

Available in 60hz or 50hz, this unit can be used and shipped complete anywhere in the world.

The generator size ranges from 30, 80, 250 and 500 kw per one 20-40 foot module. Additional modules may be combined for larger power outputs.

For biomass applications, we’re working with Energy Unlimited along with their larger biomass burners, and the Waterwide burner (seen in video).

For Geothermal applications (Enhanced Geothermal System (EGS)), you may utilized oil and gas wells, or abandoned wells that reach depths to get temperatures greater than 150 deg. C. In general, you may sink a deep well anywhere in the continental USA around a depth of 15,000 ft to reach this temperature. The diameter of the well will determine the maximum power you can reach with this type of power generating system. Another example of utilizing geothermal resources is at Chena Hot Springs, in Alaska, or The Geysers in northern California, or Puna Geothermal Venture in Hawaii, or Mammoth-Pacific geothermal power plants at Casa Diablo in California.

For cement plant applications, waste heat can be used to generate power.

For large gas turbine waste heat applications such as in powerplants, mobile power, or the offshore oil drilling installations, the turbine exhaust can be captured via a hot air to thermal oil heat exchanger and then used in the organic Rankine cycle power turbine.

If there are recip. engine generator sets (CHP), you can first use the heat to make additional power, then still use the leftover heat for CHP.

For Solar Options: Can use resource heat from parabolic trough solar, tube solar, or other means of solar heated thermal liquid.

Evaporator Exit Heat: Can be used for saltwater desalination, fresh water maker, chiller, hot water or additional process heat, such as drying and other applications (lumber dry kiln, firewood dry kiln, hardwood drykiln, greenhouse, etc.).

Condenser heat can be used for the production of secondary energy products, like hot water, chilled water or district heating, such as in radiant floor heating, or greenhouse heat.

Power Take Off: A 3,600 rpm induction or synchronous generator (50 hz or 60 hz), pump, compressor, or other shaft horsepower device can be attached.

This system may be able to access renewable (green) energy credits, as well as CO2 offset credits, which are worth as much as 25 Euro a ton.

This system is similar in function to the system at Chena Hot Springs, where a organic Rankine cycle is used to produce power from a geothermal source.

System Performance: A basic 225 kw output system will require 300 gpm of water with a temperature differential of 125 deg. F (between evaporator and condenser).

For more information:

http://www.infinityturbine.com

Duration : 0:9:0

Read the rest of this entry »

Technorati Tags: , , , , , , , , , , , ,